Monitor installation – ADS Environmental Services Model 3600 530002 A2 User Manual
Page 96
5-22
ADS 3600 Flow Monitor O&M Manual
Monitor Installation
This section contains procedures which apply to most sites. However, because
manholes differ, certain sites might require slight variations in these procedures.
Before installing the monitor at the site, verify that the monitor is configured correctly
for the applications being supported. Verify that the monitor battery is operating
correctly. (For more information on battery maintenance, see Chapter 6, “Monitor
Maintenance.”) Make any necessary changes to the configuration before mounting the
unit.
Relationship Between Installed Monitor and EMU
Installed Monitor with an IS Modem
The monitor is mounted inside the manhole by means of an aluminum flange that is
attached to the monitor and bolted to the manhole wall.
z
Hold one end of the flange against the inside of the iron manhole rim where
you wish to mount the monitor or plan to drill directly into the manhole wall.