Installing the communication cable using conduit – ADS Environmental Services Model 3600 530002 A2 User Manual
Page 84

5-10
ADS 3600 Flow Monitor O&M Manual
Y
Following the directions on the hydraulic cement can, mix enough of the
cement to apply around the conduit–both from inside and outside the
manhole.
Y
Wearing rubber gloves and using a trowel, force the cement into the hole
surrounding the conduit, then trowel a bead around the conduit. The
cement should harden in about one hour.
Note:
Wire the communication cable to the communication device before
mating the communication cable connector to the flow monitor.
Killark Series EY Sealing Fittings: Relationship between the Conduit, the Communication Cable, the Sealing Compound,
and the Close Up Plug
Installing the Communication Cable Using Conduit
Install the communication cable using conduit in the following way:
z
Find the free end of the conduit extending out of the manhole wall into the
trench. Remove the tape from this end and attach the 13 mm (0.5 in.) female
PVC adapter to this end of the conduit.
z
Lay the remaining conduit from the manhole to the pavement box. Insert the
fish tape into the conduit closest to the pavement box. Push the tape through
the conduit until it appears at the capped elbow in the manhole.
z
Find the trailing end of the communication cable (the end opposite of the
connector). Push this end up through the seal-off fitting and out the capped
elbow in the manhole. Attach this end of the cable to the fish tape using liberal