ADS Environmental Services Model 3600 530002 A2 User Manual
Page 39
4-6
ADS 3600 Flow Monitor O&M Manual
Ring Stabilizer With Spreader Mechanism Screw Inserted
2. On the open end of the ring (the end without a welded metal band), slide the
ring stabilizer and spreader mechanism screw so that the ring stabilizer flanges
are on the outside of the ring and the spreader mechanism screw is on the
inside of the ring.
Sliding Ring Stabilizer onto Ring
3. Slide the ring stabilizer all the way around the ring until it is about 10 cm or 4
in. from the welded metal band at the other end of the ring.
Moving the Ring Stabilizer into Position