ADS 3600 Flow Monitor O&M Manual
Special Installations
This topic deals with installing equipment in non-standard environments. For example,
pipes which are not round and pipes greater than 48 in. (a standard stainless steel ring
cannot be used) require a special installation.
If the site requires a special installation, usually the requirements are site-specific.
Regardless, a special installation will require two independent installations; one for the
ultrasonic sensor and one for the velocity sensor.
There are three special installation methods for the ultrasonic sensor:
l
the standard ultrasonic mount (page 4-21),
l
the adjustable ultrasonic mount (page 4-27), and
l
the surcharge mount (page 4-30).
There are two special installation methods for the velocity and pressure sensor:
l
3/4 band velocity mount installation (page 4-34) and
l
1/2 band velocity mount installation (page 4-38).
The installation methods for installing the pressure sensor are similar to the velocity
sensor. Refer to 4-36 for more information on pressure sensor installation.
Note:
In all special installations, spreader mechanisms are not used. All
mounts are installed directly to the pipe surface with the anchor bolts.