Jumper settings – ADS Environmental Services Model 3600 530002 A2 User Manual
Page 92
5-18
ADS 3600 Flow Monitor O&M Manual
1
2
3
4
5
6
7
8
Power
Time-out
Spare
106/103
Connection Type
Baud Rate
Open
Monitor will go to sleep.
Closed
Continuous power operation
Open
Time-out enabled (10 min)
Closed
Time-out disabled
Open
N/A
Closed
N/A
Open
103100 CPU
Closed
106100 CPU
Internal
Auto
Answer
Modem
Open
Open
External
Non-auto
Answer
Modem
Closed
Open
Direct
Closed
Closed
RS-232
1200
Open
Open
2400
Closed
Open
4800
Open
Closed
9600
Closed
Closed
SW3
Options Switch (Standard switch settings are shown in shaded rows.)
Jumper Settings
The following table shows the correct jumper settings for the 3600 flow monitor.
However, the only configuration that you may need to change is the battery backup
configuration. If you disable a board and place it in storage, the backup battery will
need to be re-configured prior to use. Only an ADS certified technician can disable
the board.