beautypg.com

Communications, Scada emu – ADS Environmental Services Model 3600 530002 A2 User Manual

Page 128

background image

A-10 ADS 3600 Flow Monitor O&M Manual

Communications

The following topic contains information about the EMU, SCADA EMU, and DAA.

EMU

The following table contains information and specifications for the EMU.

Functional

Description

Provides communication link between telephone network interface and 3600 monitor;
contains modem, battery, and intrinsic safety barrier; and provides modem power

Housing

Painted steel

Dimensions

15¾ inches (40 cm) high x 12¼ inches (31 cm) wide x 4 3/8 inches (11 cm) deep

Operating

Temperature

0

° to 60° C (32° to 140° F)

Power

Six 1.5-volt D-cell batteries

Inputs and

Outputs

Input: Voice-grade telephone line

Output: Communication cable to 3600 monitor

Communication

Voice-grade telemetry at 1200 bps (United States) or 2400 bps (International)

SCADA EMU

The following table contains information and specifications for the SCADA EMU.

Functional

Description

Provides communication link between telephone network interface (or RS-232) and
3600 monitor; allows RS-232 interface between 3600 monitor and SCADA system RTU;
contains modem, multiplexer board, power supply, backup battery, and intrinsic safety
barrier; accepts external power

Housing

Painted steel

Dimensions

15¾ inches (40 cm) high x 12¼ inches (31 cm) wide x 4 3/8 inches (11 cm) deep

Operating

Temperature

0

° to 60° C (32° to 140° F)

Power

External AC power with NiCad battery for 6-8 hours operational power during power
failure

External DC power

Inputs and

Outputs

Inputs: AC or DC power; voice-grade telephone line

Outputs: Communication cable to 3600 monitor; RS-232 interface to SCADA system
RTU

Communication

Direct: RS-232 serial communication

Remote: 14.4 Kbps modem