Ring, Sensor, and Special Installations
4-15
l
Position the spreader assembly handle facing you. On the right-hand side of
the ring, begin to secure the velocity and pressure cables along the trailing edge
of the ring in a clockwise direction. Attach the cable to the ring with cable ties
that are 4 in. (10 cm) long and 0.08 in. (2 mm) wide. Pull the ties until they are
taut. Continue this process until you reach the ultrasonic sensor. Cut off the
excess portion of the cable ties.
Note:
When mounting a pressure and a velocity sensor cable to the ring,
place the velocity cable on top of the pressure cable and secure both together.
See the following figure for more information about cabling.
TOP VIEW
SIDE VIEW
Mounting Metal
Cable Ties
Correct
Incorrect
Velocity
Pressure
93/3064
Mounting Metal
Sensor Cabling