Great Plains PTO Kits 2-3-Section User Manual
Page 63
Great Plains Manufacturing, Inc.
Appendix A - Installation
59
2014-09-10
411-015M
Hydraulic
Connections
Call-
out
Part
Hose Description
Comments
Fan Pressure hose
from hitch
,
Existing Hose
Remove hose handles. Disconnect from fan. Reconnect
hitch end to PTO pump outlet. Reconnect rear end to
flow control valve port P.
Fan Case Drain
hose
Existing Hose
Remove QD fittings at hitch end. Connect hitch end to
reservoir case drain inlet.
Fan Return hose
from hitch
,
Existing Hose
Remove hose handles. Disconnect from fan. Reconnect
hitch end to reservoir inlet. Reconnect fan end to cooler
outlet extension hose
.
Fan motor loop
Existing Hose
Left undisturbed.
Fan Return hose
811-269C
HH1/2R2 036 3/4FJIC
Connects fan outlet to flow control valve port T.
Fan Supply hose
811-269C
HH1/2R2 036 3/4FJIC
Connects flow control valve port M to fan inlet.
Cooler Inlet hose
811-279C
HH1/2R2 060 3/4FJIC
Connects flow control valve port T to cooler inlet.
Cooler Outlet hose
841-506C
HH1/2R2 030 3/4MJIC
3/4FJIC
Connects cooler outlet to fan end of existing fan return
hose
.
PTO Pump supply
hose
841-920C
HH1 1/4R4 070 1 5/8FJIC
Connects reservoir outlet to PTO pump inlet.
A
B
C
D
E
272
L
241
241
242
272
E
282