3. A
SSEMBLY
X160-85, X160-105, X160-125
30875 R0
75
Important:
The X160-85 model requires four 5/16” cable clamps (19333) per cable, and the
X160-105/125 models require four 1/2” cable clamps (20606) per cable.
4. Tie up excess ends of lift cable with tape or cable ties.
Important:
Lift cables will stretch with initial use. Check and adjust frequently.
Figure 3.29 Connecting the Lift Cylinder Cables
WARNING
Ensure that cable clamps are positioned with
the U-bolt portion of the clamp on the
unloaded side of the lift cables (see Figure
3.29).
Tighten 1/2” cable clamp nuts to 60 ft-lbs, and
5/16” cable clamp nuts to 35 ft-lbs, as
measured by a recently and accurately
calibrated torque wrench.
Failure to tighten the nuts properly could
cause the main auger tube to drop from a
raised position quickly and without warning,
and could lead to personal injury or death.