Electro-magnetic interference (emi) immunity, Power harmonics and flicker, Safety compliance – ClearCube R Series Pentium 4 User Manual
Page 128

118 • Appendix B – Regulatory Compliance
ClearCube Product Manual and Installation Guide
Electro-Magnetic Interference (EMI) Immunity
This equipment was also tested in accordance with the procedures given in the EN
55024: 1998 – Information Technology Equipment, Immunity Characteristics – Limits
and methods of measurements and was found to comply with:
•
EN 61000-4-2: 1995, Electrostatic Discharge Immunity Test, performance criteria:
4/8 kV
•
EN 61000-4-3: 1995, Immunity to Radiated, Radio Frequency, Electromagnetic
Fields, performance criteria: 3 V/m
•
EN 61000-4-4: 1995, Electrical Fast Transient/Burst Requirements, performance
criteria: 1 kV/.5 kV
•
EN 61000-4-5: 1995, Surge Immunity Requirements, performance criteria: 2/1 kV
•
EN 61000-4-6: 1996, Conducted Disturbance Induced by Radio-Frequency Fields
Immunity, performance criteria: 3 Vrms
•
EN 61000-4-8: 1994, Power Frequency Magnetic Field Immunity, performance
criteria: 1 A/m
•
EN 61000-4-11: 1994, Voltage Dips, Short Interruptions and Voltage Variations
Immunity, performance criteria: 95%-5c and 250c, 30%-25s
Power Harmonics and Flicker
Other requirements that this equipment has been found to comply with are:
•
EN 61000-3-2: 1995, Limits for Harmonic Current Emissions (equipment input
less than or equal to 16 A per phase)
•
EN 61000-3-3: 1995, Limitation of Voltage Fluctuations and Flicker in Low Voltage
Supply Systems for Equipment with rated Current = 16 A
Safety Compliance
The C3-R Cage, R1200 Blade, R2100 Blade, C/Port and MVX was tested and is
certified to the following safety standards:
•
UL 60950 3
rd
Ed., 7-28-95 with revisions through and including 3-1-98, TUV
Rheinland of N.A. (an OSHA accredited Nationally Recognized Test Laboratory)
Certificate CU72040336.
•
CAN/CSA-C22.2 No. 60950-00, TUV Rheinland of N.A. Certificate CU72040336
•
IEC 60950:1999, CB certificate US-TUVR-2088
Country Deviations from CB Bulletin 107a considered under the scope of the above certificate are, but
may not be limited to; Argentina, Austria, Australia, Belgium, Brazil, Canada, Switzerland, China,
Czech Republic, Germany, Denmark, Spain, Finland, France, United Kingdom, Hungary, Ireland,
Israel, India, Italy, Japan, Korea, Malaysia, Netherlands, Norway, Poland, Portugal, Russia, Sweden,