Chapter 12

Configuring Hardware for the MicroVAX

Information Processors

12-13

Verify Disk

The names of the disks you have are:

DUA0 = disk 1
DUA1 = disk 2

To verify a disk, follow this procedure.

1.

Make sure you are at the console prompt, then enter:

TEST 71

2.

You see:

VSmsv QUE–unitno (0–1)?

3.

Enter 0 to verify disk DUA0 or 1 to verify disk DUA1.

If you see:

VSmsv_STS_Siz . . . . . RD54

VSmsv_QUE_RUsure (DUA0 1/0) ?

then the disk has already been formatted.

If you see:

VSmsv_STS_Siz . . . . . ??

VSmsv_RES_Err #2
84 FAIL
>>>>

then the disk has not been formatted or a problem has occurred. Go
to the formatting procedure in the next section.

4.

To make sure the formatted disk is in good operating condition,
enter

1

.

If you see a display similar to this:

VSmsv_STS_RDing . . . . . OK

VSmsv_STS_OBBcnt = 14

VSmsv_NBBcnt – 0