Rockwell Automation 5000,D50006.2.10 PI INSTALLATION MANUAL User Manual
Page 147
Chapter 12
Configuring Hardware for the MicroVAX
Information Processors
12-9
If this device:
Then:
Displays this selfĆtest
error code:
HDC
1
7770.0001
0 disks are connected to the module and the device is good.
7710.0001
1 disk is connected to the module and the device is good (DUA1).
7110.0001
2 disks are connected to the module and the device is good (DUA0).
7ABC.WXYZ
where:
A = drive DUA1
B = drive DUA0
X = control status for DUA1
Y = control status for DUA0
if either X or Y is:
2, 4, 6, 8, A, C, E
there is a fatal error. Replace disk or call AĆB representative.
if either X or Y is:
5,F
check to see if disk is formatted. If the disk is formatted, it indicates a
controller error. Call AĆB representative.
if either X or Y is:
3,9
it is a warning. Try again.
7777.7777
check that drive has power and cables are properly connected,
replace the specified disk.
TPC
1
0000.0001
the tape controller and the program loader are good.
0000.4001
the tape controller is good and the program loader is not connected.
WXYZ.0001
and WX=YZ
and WX<>YZ
then the module is communicating with the program loader.
disconnect the program loader cable (turn off program loader, unplug
data cable, then unplug power cable. See Appendix B for more
information) and run the selfĆtest again (TEST 6).
•
if you don't see 0000.4001, replace the cable and run the
selfĆtest again.
•
if you see 0000.4001, reconnect the cable, power down the
system and power up the system again. Run the selfĆtest again.
You should then see 1212.0001. If you don't see 1212.0001, run
the system exerciser.
WXYZ.ABCD
and CD>01
replace the module.
and B is:
1
2
3
check that program loader has power and cables are properly
connected then:
replace the module.
replace the program loader.
replace both.
and A is:
1
check that program loader has power and cables are properly
connected then:
retest TPC.
3
retest the program loader.
4
replace the module and the program loader.
5
the controller doesn't recognize the program loader. Follow the
procedure above for when WX<>YZ.
6
retest TPC and the program loader. Follow the procedure above for
when WX<>YZ.
7
replace the program loader.
1
MicroVAX Information Processor (cat. no. 5730ĆCPU1) only.