General Purpose I/O (GPIO Connector)
Two 24V digital outputs are user programmable. You can monitor the status the
an optional regenerative power supply. An isolated, external 24V DC power
source must be customer supplied to power the digital outputs.
Table 21 - General Purpose I/O Digital Output Specifications
The two DC current sourcing outputs default settings are Zero_Speed
(Digital_Out_1) and In_Position (Digital_Out_2). Zero_Speed is the motor at
0 rpm velocity. In_Position can be set to the commanded position by the Position
Lock Tolerance (set in Axis Properties/Limits). Default parameter selections can
also be set with an IDN function.
Figure 39 - General Purpose I/O Digital Output Diagram
Pin
Signal
Description
On Condition
Off Condition Leakage
1
Digital_Out_1
Optically isolated to 500V, current sourcing up to 75 mA
24…40V DC
<0.25 mA
2
DO_24VDC_1
24V DC power source to digital inputs (customer-supplied)
—
—
3
DO_24VDC_2
4
Digital_Out_2
Optically isolated to 500V, current sourcing up to 75 mA
24…40V DC
<0.25 mA
5
Reserved
6
1
k
Ω
0.1
μ
F
3.32
k
Ω
10
Ω
10
Ω
1
k
Ω
0.1
μ
F
3.32
k
Ω
DO_24VDC_1
Digital_Out_1
DO_24VDC_2
Digital_Out_2
Dig_Out_1