Noise reduction guidelines for drive accessories – Rockwell Automation 2099-BMxx Kinetix 7000 High Power Servo Drive User Manual User Manual
Page 36

36
Rockwell Automation Publication 2099-UM001D-EN-P - December 2012
Chapter 2
Install the Kinetix 7000 Drive System
Table 6 - Line Interface Module
Table 7 - External Shunt Resistor Kit
Noise Reduction Guidelines for Drive Accessories
When mounting an AC (EMC) line filter or external shunt resistor refer to the
sections below for guidelines designed to reduce system failures caused by
excessive electrical noise.
AC Line Filters
Observe the following guidelines when mounting your AC (EMC) line filter.
See the
Establishing Noise Zones (AC Power)
on page
33
for an example.
• Mount the ac line filter on the same panel as the Kinetix 7000 drive and as
close to the power input as possible.
• Good HF bonding to the panel is critical.
For painted panels, refer to the examples on page 29.
• Segregate input and output wiring as far as possible.
Wire/Cable
Connector
Zone
Method
Very
Dirty
Dirty
Clean
Ferrite
Sleeve
Shielde
d Cable
VAC line (main input)
IPL
X
230V AC input
APL
X
VAC load (shielded option)
OPL
X
X
VAC load (unshielded option)
X
Control power output
CPL
X
MBRK PWR, MBRK COM
P1L/PSL
X
Status I/O
IOL
X
Auxiliary 230V AC
P2L
X
Wire/Cable
Connector
Zone
Method
Very
Dirty
Dirty
Clean
Ferrite
Sleeve
Shielded
Cable
COL, DC+ (shielded option)
RC
X
X
COL, DC+ (unshielded option)
X
Thermal switch
TS
X
X
Fan (if present)
N/A
X
IMPORTANT
CE test certification applies only to ac line filter and single drive. Sharing a
line filter with multiple drives may perform satisfactorily, but the user takes
legal responsibility.