Power specifications, E power specifications – Rockwell Automation 2099-BMxx Kinetix 7000 High Power Servo Drive User Manual User Manual
Page 150

150
Rockwell Automation Publication 2099-UM001D-EN-P - December 2012
Appendix A
Specifications and Dimensions
Power Specifications
This section contains power specifications for the Kinetix 7000 drive.
Attribute
2099-BM06-S
2099-BM07-S
2099-BM08-S
2099-BM09-S
2099-BM10-S
2099-BM11-S
2099-BM12-S
AC input voltage
342…528V AC rms three-phase (380…480V nom)
AC input frequency
47…63 Hz
Bandwidth
(1)
Velocity loop
Current loop
500 Hz
1300 Hz
500 Hz
500 Hz
PWM frequency
4 kHz
2 kHz
Main AC input current
Nom (rms)
Max inrush (A peak)
36.7 A
18.0 A
47.7 A
18.0 A
59.6 A
18.0 A
90.1 A
96.0 A
117 A
118 A
169 A
141 A
233 A
141 A
DC input voltage
450…750V DC
DC input current
42.9 A
55.7 A
69.7 A
105 A
137 A
204 A
281 A
Control power input Voltage
18…30V DC (24V DC, nom)
Control power DC input current
Nom (rms)
Maximum inrush (rms)
3.3 A
6.0 A
Continuous output current (rms)
40.0 A
52.0 A
65.0 A
96.0 A
125 A
180 A
248 A
Continuous output current (0-pk)
56.0 A
73.0 A
92.0 A
135 A
176 A
254 A
351 A
Peak output current (rms)
3 s duration
60 s duration
68.0 A
51.0 A
80.0 A
60.0 A
104 A
78.0A
154 A
115 A
163 A
138 A
312 A
234 A
372 A
273 A
Peak output current (0-pk)
3 s duration
60 s duration
96.0 A
72.0 A
113 A
84.8 A
147 A
110 A
217.7 A
162.6 A
230.5 A
195 A
441 A
331 A
526 A
386 A
Bus overvoltage
800V DC
Bus undervoltage
275…560V DC
(2)
Continuous power output, nom
22 kW
30 kW
37 kW
56 kW
75 kW
112 kW
149 kW
Continuous power output (Hp)
30 Hp
40 Hp
50 Hp
75 Hp
100 Hp
150 Hp
200 Hp
Maximum power cycles/minute
AC line
DC bus
4 per minute (pre-charge provided by drive)
2 per minute (DC pre-charge provided by the regenerative power supply)
DC bus discharge time
3 minutes after removal of main AC power
Efficiency
97.5%
Total capacitance
(3)
1800
μ
F
2400
μ
F
3000
μ
F
4500
μ
F
6000
μ
F
8400
μ
F
8400
μ
F
Short circuit current rating
200,000 A (rms) symmetrical
(1) Bandwidth values vary based on tuning parameters and mechanical components.
(2) Bus undervoltage will vary based on input line voltage.
(3) If DC input is supplied to 2099-BM09-S, 2099-BM10-S, 2099-BM11-S, or 2099-BM12-S drives, the precharge capability must be provided at the system level. Disconnect switches must not be used
between the input of the drive and a common DC bus without the use of an external precharge device.