Configure the Module in a GuardLogix Controller System
Chapter 5
g. From the Input Status pull-down menu, choose from the following.
h. From the Data Format pull-down menu, use the default ‘Integer’.
5. Click OK to return to the Module Properties dialog box.
Choose
Description
None
There are no status tags, only data for the outputs.
Pt. Status
There is one status tag for each output point.
Pt. Status - Readback
• There is one status tag for each output point.
• There is one data tag for the output readback.
Combined Status -
Readback - Power
• A single BOOL tag represents an AND of the status bits for all the output
points. For example, if any output channel has a fault, this bit goes LO.
(1)
• There is one data tag for the output readback.
• A single BOOL tag represents the Output Power Status (error bit) from the
input assembly.
(1) When using combined status, use explicit messaging to read individual point status for diagnostic purposes.