Class attributes instance attributes – Rockwell Automation 1203-CN1 ControlNet Communications Module 1203-CN1 User Manual
Page 113

Publication 1203-5.13 – February, 2002
ControlNet Objects: Class Code 0x97 — SCANport Pass-Through Fault Object
D-27
Class Code 0x97 — SCANport
Pass-Through Fault Object
The SCANport Pass-Through Fault Object provides information on
the product’s fault queue.
Class Attributes
Instance Attributes
Attribute ID
Access Rule
Name
Data Type
Description
0
Set
Write Fault
Command
BYTE
1 = Clear Faults
2 = Clear Fault Queue
3 = Reset Product
1
Get
Read Number of
Fault Queue Entries
BYTE
Reads the number of fault queue entries.
2
Get
Read Fault Queue
Trip Index
BYTE
Reads the index of the fault that tripped
the product.
Attribute ID
Access Rule
Name
Data Type
Description
0
Get
Read Fault Queue
Entry Full/All Info
STRUCT of
Fault Text
ARRAY of BYTE 16 character string (no length
information, no terminating null).
Fault Code
WORD
Fault Code.
Fault Time Stamp
STRUCT
BYTE
1/100 Second (0 – 99).
BYTE
Second (0 – 59).
BYTE
Minute (0 – 59).
BYTE
Hour (0 – 23).
BYTE
Day of Week (0 – 6).
➀
BYTE
Date (1 – 31).
BYTE
Month (1 – 12).
BYTE
Year (0 – 99
➁
).
128
Get
Fault Code and
Time Stamp
STRUCT of
Fault Code
WORD
Fault Code.
Fault Time Stamp
STRUCT of
BYTE
1/100 Second (0 – 99).
BYTE
Second (0 – 59).
BYTE
Minute (0 – 59).
BYTE
Hour (0 – 23).
BYTE
Day of Week (0 – 6).
➀
BYTE
Date (1 – 31).
BYTE
Month (1 – 12).
BYTE
Year (0 – 99
➁
).
129
Get
Read Fault Text
String Only
ARRAY of BYTE 16 character string (no length
information, no terminating null).
➀
Sunday is a value of zero.
➁
Year is an offset from 1990.