Seam-loc 24, 24 m – Metal Sales Seam-Loc 24 Installation User Manual
Page 63
© Metal Sales Manufacturing Corporation/ Subject to change without notice/ Effective Date 12/03
800.406.7387 (Corporate Office) • www.metalsales.us.com
62
SEAM-LOC 24
®
I
NSTALLATION
OF
S
EAM
-L
OC
24 M
ETAL
O
UTSIDE
C
LOSURE
Note: The Metal Outside Closure is used to close off the high end of the panel applications for open framing. Before
installation of Metal Outside Closure can begin, all roof panels must be seamed. (See seaming panels on pages 35 and
36 for proper seaming instructions.)
Steps:
1. Once panels have been installed and seamed, slide Compression Plate under upper edge of panels. Position Compression Plate
to allow for proper installation of flashing assembly. Use C-clamps to hold Compression Plate in place.
2. Apply Double Bead Tape Sealant down the female leg. across the panel and up the male leg 1
1
/
2
" from the end of the panel.
3. Place the Metal Outside Closure on Double Bead Tape Sealant making sure the punched lower leg is towards the ridge. The
punched lower leg should be 1
1
/
2
" from the end of the panel. Use screw driver to properly align panel, closure, and
compression plate.
4. Fasten the Metal Outside Closure with (6) #12-14 x 1" SD NW screws. Fasteners must penetrate the Metal Outside
Closure, sealant, panel, and Compression Plate.
5. Apply a continuous
3
/
8
" diameter bead of Tube Sealant (if necessary) where the Metal Outside Closure meet the panel seams
and fill any and all gaps left around closure.
Pig Tail of Double Bead Tape Sealant
INSTALLATION NOTES
Seam-Loc 24 Metal Outside Closure
Seam-Loc 24 Metal Outside Closure
Screw Driver
Seam-Loc 24 Metal Outside Closure
Tube Sealant
#12-14 x 1" Self Driller N/W
2
1
5
6
4
3