SEAM-LOC 24

®

I

NSTALLATION

OF

S

EAM

-L

OC

24 M

ETAL

O

UTSIDE

C

LOSURE

Note: The Metal Outside Closure is used to close off the high end of the panel applications for open framing. Before

installation of Metal Outside Closure can begin, all roof panels must be seamed. (See seaming panels on pages 35 and

36 for proper seaming instructions.)

Steps:

1. Once panels have been installed and seamed, slide Compression Plate under upper edge of panels. Position Compression Plate

to allow for proper installation of flashing assembly. Use C-clamps to hold Compression Plate in place.

2. Apply Double Bead Tape Sealant down the female leg. across the panel and up the male leg 1

1

/

2

" from the end of the panel.

3. Place the Metal Outside Closure on Double Bead Tape Sealant making sure the punched lower leg is towards the ridge. The

punched lower leg should be 1

1

/

2

" from the end of the panel. Use screw driver to properly align panel, closure, and

compression plate.

4. Fasten the Metal Outside Closure with (6) #12-14 x 1" SD NW screws. Fasteners must penetrate the Metal Outside

Closure, sealant, panel, and Compression Plate.

5. Apply a continuous

3

/

8

" diameter bead of Tube Sealant (if necessary) where the Metal Outside Closure meet the panel seams

and fill any and all gaps left around closure.

Pig Tail of Double Bead Tape Sealant

INSTALLATION NOTES

Seam-Loc 24 Metal Outside Closure

Seam-Loc 24 Metal Outside Closure

Screw Driver

Seam-Loc 24 Metal Outside Closure

Tube Sealant

#12-14 x 1" Self Driller N/W

2

1

5

6

4

3