beautypg.com

Seam-loc 24, Ssr r – Metal Sales Seam-Loc 24 Installation User Manual

Page 62

background image

© Metal Sales Manufacturing Corporation/ Subject to change without notice/ Effective Date 12/03

800.406.7387 (Corporate Office) • www.metalsales.us.com

61

SEAM-LOC 24

®

INSTALLATION NOTES

SSR R

IDGE

O

VER

R

IGID

I

NSULATION

SSR Ridge

Seam-Loc 24 Compression Plate

#12-14 x 1" Self Driller N/W (see below)

#

1

/

4

-14 x

7

/

8

" Stitch XL (3 per panel)

Double Bead Tape Sealant

Seam-Loc 24 Metal Outside Closure

Double Bead Tape Sealant

Seam-Loc 24 Panel

1

1

/

2

"

3"

CL

Seam-Loc 24 Clip with (2) #14-13 x (X") Dekfast

Bearing Plate

Note: Lengths of Dekfast screws are

dependent on the assembly thickness

(see page 17 for lengths).

Seam-Loc 24 Fastening Pattern

D. B. T. S.

Metal Outside Closure

#12-14 x 1" SD N/W

2

6

5

4

1

3

1. Once panels have been installed, slide Compression Plate under upper edge of panels. Position Compression Plate to allow

for proper installation of ridge assembly. Use C-clamps to hold Compression Plate in place.

2. Apply a row of Double Bead Tape Sealant across panel, up and over all ribs approximately 1

1

/

2

" from panel end on both sides

of ridge.

3. Install Seam-Loc 24 Outside Closures over Tape Sealant. Before continuing make sure Outside Closure placement will

accommodate SSR Ridge.

4. Once Closure is set in Tape Sealant, fasten through Outside Closure, Tape Sealant, Seam-Loc 24 panel, and into Compression

Plate with (6) #12-14 x 1" SD N/W per panel. C-clamps may be removed once Closures have been fastened.

5. Once all Outside Closures have been installed, place a row of Double Bead Tape Sealant across top of Outside Closures on both

sides of ridge. Tube Sealant must be used to fill any and all gaps left around Outside Closures.

6. Install SSR Ridge flashing and secure to top leg of Outside Closures with #

1

/

4

-14 x

7

/

8

" Stitch XL at the spacing shown above.

7. If two or more flashings are required, lap the flashing over the previously installed flashing by a minimum of 2" placing a

bead of Tube Sealant between the flashings and securing with Pop Rivets, 2

1

/

2

" o.c.