SEAM-LOC 24

®

INSTALLATION NOTES

SSR S

CULPTURED

R

AKE

(O

FF

M

ODULE

) O

VER

R

IGID

I

NSULATION

SSR Rake Slide

Double Bead Tape Sealant

Seam-Loc 24 Panel (field cut rib and bend

up to match height of Rake Angle)

Floating Rake Angle

SSR Rake Cleat

SSR Sculptured Rake (off module)

#

1

/

4

-14 x

7

/

8

" Stitch Screw XL (1'-0" o.c.)

#12-14 x 1

1

/

4

" Self Driller XL (1'-0" o.c.)

#12-14 x 1

1

/

4

" Shoulder Self Driller XL (1'-0" o.c.)

#

1

/

4

-14 x

7

/

8

" Stitch Screw XL (1'-0" o.c.)

Double Bead Tape Sealant

Rake Angle

Seam-Loc 24 Floating Rake Angle and Seam-Loc 24 panels must be installed prior to SSR Sculptured Rake installation

(See Pages 24-36).

1. With Seam-Loc 24 panel nested against Seam-Loc 24 Floating Rake Angle, apply a row of Double Bead Tape sealant across

upper side of field bent panel rib. (See page 34 for proper bending of panel.)

2. Install SSR Rake Cleat over Double Bead Tape Sealant. Fasten through SSR Rake Cleat, Tape Sealant, panel, and into

Floating Rake Angle with #12-14 x 1

1

/

4

" Self Driller XL screws, 1'-0"o.c.

3. Apply a row of Double Bead Tape Sealant across top leg of SSR Rake Cleat.

4. Install SSR Sculptured Rake flashing so that top of flashing is flush with top of SSR Rake Cleat and panel rib. Fasten

through SSR Sculptured Rake, Tape Sealant, and into SSR Rake Cleat with #1⁄4-14 x

7

/

8

" Stitch XL, 1'-0"o.c.

5. Position and apply a row of Double Bead Tape Sealant across wall panel just below lower leg of SSR Rake flashing.

6. Install SSR Rake Slide over lower leg of SSR Rake flashing and Double Bead Tape Sealant. Fasten with #

1

/

4

-14 x

7

/

8

"

Stitch XL, 1'-0"o.c.

7. If two or more flashings are required, lap the flashing over the previously installed flashing by a minimum of 2" placing a

bead of Tube Sealant between the flashings and securing with Pop Rivets, 2

1

/

2

" o.c.