Seam-loc 24, Ssr s – Metal Sales Seam-Loc 24 Installation User Manual
Page 42
![background image](/manuals/567698/42/background.png)
© Metal Sales Manufacturing Corporation/ Subject to change without notice/ Effective Date 12/03
800.406.7387 (Corporate Office) • www.metalsales.us.com
41
SEAM-LOC 24
®
SSR S
CULPTURED
R
AKE
(O
FF
M
ODULE
) D
ETAIL
SSR Rake Slide
Double Bead Tape Sealant
SSR Sculptured Rake (off module)
#
1
/
4
-14 x
7
/
8
" Stitch XL (1'-0" o.c.)
SSR Rake Cleat
#12-14 x 1
1
/
4
" SD XL (1'-0" o.c.)
Seam-Loc 24 Panel (bend up to match
height of Floating Rake Angle)
Double Bead Tape Sealant
#12-14 x 1
1
/
4
" Shoulder SD (1'-0" o.c.)
Floating Rake Angle
Rake Angle
#
1
/
4
-14 x
7
/
8
" Stitch XL (1'-0" o.c.)
Seam-Loc 24 Floating Rake Angle and Seam-Loc 24 panels must be installed prior to SSR Sculptured Rake installation
(See Pages 24-36).
1. With Seam-Loc 24 panel nested against Seam-Loc 24 Floating Rake Angle, apply a row of Double Bead Tape sealant across
upper side of field bent panel rib. (See page 34 for proper bending of panel.)
2. Install SSR Rake Cleat over Double Bead Tape Sealant. Fasten through SSR Rake Cleat, Tape Sealant, panel, and into
Floating Rake Angle with #12-14 x 1
1
/
4
" Self Driller XL screws, 1'-0"o.c.
3. Apply a row of Double Bead Tape Sealant across top leg of SSR Rake Cleat.
4. Install SSR Sculptured Rake flashing so that top of flashing is flush with top of SSR Rake Cleat and panel rib. Fasten
through SSR Sculptured Rake, Tape Sealant, and into SSR Rake Cleat with #1⁄4-14 x
7
/
8
" Stitch XL, 1'-0"o.c.
5. Position and apply a row of Double Bead Tape Sealant across wall panel just below lower leg of SSR Rake flashing.
6. Install SSR Rake Slide over lower leg of SSR Rake flashing and Double Bead Tape Sealant. Fasten with #
1
/
4
-14 x
7
/
8
"
Stitch XL, 1'-0"o.c.
7. If two or more flashings are required, lap the flashing over the previously installed flashing by a minimum of 2" placing a
bead of Tube Sealant between the flashings and securing with Pop Rivets, 2
1
/
2
" o.c.
INSTALLATION NOTES
1
/
4
:12 Slope
Minimum