beautypg.com

Seam-loc 24 – Metal Sales Seam-Loc 24 Installation User Manual

Page 51

background image

© Metal Sales Manufacturing Corporation/ Subject to change without notice/ Effective Date 12/03

800.406.7387 (Corporate Office) • www.metalsales.us.com

50

SEAM-LOC 24

®

V

ENTED

R

IDGE

O

VER

O

PEN

F

RAMING

1. Once panels have been installed, slide Compression Plate under the upper edge of panels. Position Compression Plate to

allow for proper installation of vented ridge assembly. Use C-clamps to hold Compression Plate in place.

2. Apply a row of Double Bead Tape Sealant across panel, up and over all ribs approximately 1

1

/

2

" from panel end on

both sides of ridge.

3. Install Seam-Loc 24 Outside Closures over Tape Sealant. Before continuing make sure Outside Closure placement will

accommodate Vented Ridge Cover.

4. Once closure is set in Tape Sealant, fasten through Outside Closure, Tape Sealant, Seam-Loc 24 panel, and into Compression

Plate with (6) 12-14 x 1" SD N/W per panel. C-clamps may be removed once Closures have been fastened.

5. Once all Outside Closures have been installed, place a row of Double Bead Tape Sealant across top of Outside Closures on both

sides of ridge. Tube Sealant must be used to fill any and all gaps left around Outside Closures.

6. Install Vent Drip, Vent Material, and Offset Cleat (in order) and fasten to top leg of Outside Closure with #14 Dekfasts at 1'-0"o.c.

7. Apply a row of Double Bead Tape Sealant across outer leg of Offset Cleat.

8. Install Vented Ridge Cover and secure to outer leg of Offset Cleat with Pop Rivets at 1'-0"o.c.

9. If two or more flashings are required, lap the flashing over the previously installed flashing by a minimum of 2" placing a

bead of Tube Sealant between the flashings and securing with Pop Rivets 2

1

/

2

" o.c.

INSTALLATION NOTES

Vented Ridge Cover

Compression Plate

#12-14 x 1" SD N/W (see below)

1

/

8

x

13

/

16

" Pop Rivet (1'-0" o.c.)

Double Bead Tape Sealant

Seam-Loc 24 Metal Outside Closure

Double Bead Tape Sealant

Clip with (2) #

1

/

4

-14 x 1

1

/

2

" SD N/W

Seam-Loc 24 Panel

11"

1

1

/

2

"

1"

CL

Vent Drip

Vent Material

Offset Cleat

#14-13 x 2" Dekfast (1'-0" o.c.)

Double Bead Tape Sealant

Note: Refer to page 19 for

proper ventilation

considerations.

3:12 Slope

Minimum

Seam-Loc 24 Fastening Pattern

D. B. T. S.

Metal Outside Closure

#12-14 x 1" SD N/W

2

6

5

4

1

3