beautypg.com

Seam-loc 24 – Metal Sales Seam-Loc 24 Installation User Manual

Page 49

background image

© Metal Sales Manufacturing Corporation/ Subject to change without notice/ Effective Date 12/03

800.406.7387 (Corporate Office) • www.metalsales.us.com

48

SEAM-LOC 24

®

S

CULPTURED

H

IGH

S

IDE

E

AVE

O

VER

O

PEN

F

RAMING

1. Once panels have been installed, slide Compression Plate under upper edge of panels. Position Compression Plate to allow

for proper installation of High Side Eave assembly. Use C-clamps to hold Compression Plate in place.

2. Apply a row of Double Bead Tape Sealant across panel, up and over all ribs approximately 1

1

/

2

" from panel end.

3. Install Seam-Loc 24 Outside Closures over tape sealant. Before continuing make sure Outside Closure placement will

accommodate SSR Sculptured High Side Eave flashing.

4. Once Closure is set in Tape Sealant, fasten through Outside Closure, Tape Sealant, Seam-Loc 24 panel, and into Compression

Plate with (6) 12-14 x 1" SD N/W per panel. C-clamps may be removed once closures have been fastened.

5. Once all Outside Closures have been installed, place a row of Double Bead Tape Sealant across top of Outside Closures. Tube

Sealant must be used to fill any and all gaps left around Outside Closures.

6. Install SSR Sculptured High Side Eave flashing and secure to top leg of Outside Closures with #

1

/

4

-14 x

7

/

8

" Stitch XL at the

spacing shown above.

7. Fasten SSR Sculptured High Side Eave flashing to finished wall with appropriate fastener, 1'-0"o.c.

8. If two or more flashings are required, lap the flashing over the previously installed flashing by a minimum of 2" placing a

bead of Tube Sealant between the flashings and securing with Pop Rivets, 2

1

/

2

" o.c.

INSTALLATION NOTES

SSR Sculptured High Side Eave

Compression Plate

#12-14 x 1" SD N/W (See Below)

#

1

/

4

-14 x

7

/

8

" Stitch XL (3 per panel)

Double Bead Tape Sealant
Seam-Loc 24 Metal Outside Closure

Double Bead Tape Sealant

Clip with (2) #

1

/

4

-14 x 1

1

/

2

" SD N/W

Seam-Loc 24 Panel

1

1

/

2

"

Double Bead Tape Sealant
#

1

/

4

-14 x

7

/

8

" Stitch XL (1'-0" o.c.)

1

/

4

:12 Slope

Minimum

Seam-Loc 24 Fastening Pattern

D. B. T. S.

Metal Outside Closure

#12-14 x 1" SD N/W

2

6

5

4

1

3