beautypg.com

Seam-loc 24 – Metal Sales Seam-Loc 24 Installation User Manual

Page 52

background image

© Metal Sales Manufacturing Corporation/ Subject to change without notice/ Effective Date 12/03

800.406.7387 (Corporate Office) • www.metalsales.us.com

51

SEAM-LOC 24

®

S

CULPTURED

E

AVE

O

VER

R

IGID

I

NSULATION

INSTALLATION NOTES

Seam-Loc 24 Sculptured Eave

#12-14 x 1" SD N/W (see below)

Seam-Loc 24 Metal Inside Closure (see below)

Double Bead Tape Sealant

#

1

/

4

-14 x

7

/

8

" Stitch Screw XL (1'-0" o.c.)

Seam-Loc 24 Panel

Eave Plate

Tube Sealant

Double Bead Tape Sealant

1

/

4

:12 Slope

Minimum

Seam-Loc 24 Fastening Pattern

D. B. T. S.

#12-14 x 1" SD N/W

Metal

Inside

Closure

#12-14 x 1

1

/

4

" SD XL

2

6

5

4

1

3

#14-13 x (X") Dekfast (1'-0" o.c.)

Note: Lengths of Dekfast screws are dependent on

the assembly thickness (see page 17 for lengths).

All Eave flashings must be installed prior to panel installation.

1. Install Sculptured Eave back against previously installed Eave Plate, (see page 25 for Eave Plate installation). To hold

Sculptured Eave in place fasten to substrate with #10-16 x 1" Pancake Head fastener, 4'-0" o.c.

2. Fasten Sculptured Eave to wall with appropriate fastener, 1'-0" o.c.

3. Apply a row of Double Bead Tape Sealant across Sculptured Eave so that sealant is centered over top leg of Eave Plate.

4. If two or more flashings are required, lap the flashing over the previously installed flashing by a minimum of 2" placing a

bead of Tube Sealant between the flashings and securing with Pop Rivets, 2

1

/

2

" o.c.

5. Once panels and inside closures have been installed and properly sealed, (See page 26), fasten through panel, Double Bead Tape

Sealant, and Sculptured Eave into Eave Plate with (6) #12-14 x 1

1

/

4

" Self Driller XL screws per panel.