EDS94AYCCA EN 5.0 - 06/2012

L

53

E94AYCCA communication manual (CANopen®)

Process data transfer

Synchronisation of PDOs via sync telegram

Sync application cycle
This parameter influences the effect of the sync phase position (

C01122

) with regard to the

instant of acceptance of the synchronous PDOs by the application or the instant of

transmission of the synchronous PDOs to the system bus (CANopen).

For Servo Drive 9400 software versions lower than V3.0 the following applies:

 The sync application cycle is permanently set to 1000 μs.
 The resulting PDO delay can be calculated with the following formula taking into

consideration an internal processing time of 150 s:

PDO delay= (sync cycle time - sync phase position + 150 μs) modulo 1000

From Servo Drive 9400 software version V3.0 the following applies:

 The sync application cycle can be set in

C01130

. The value set is automatically rounded

down to full 1000 μs.

 The resulting PDO delay can be calculated with the following formula, taking an

internal processing time of 150 s into consideration:

PDO delay= (sync cycle time - sync phase position + 150 μs) modulo

C01130

Note!

If the sync application cycle in

C01130

is set higher than the sync cycle time

(

C01121

), the response is undefined. The same applies if the sync phase position

(

C01122

) is set higher than the sync cycle time (

C01121

).

In these cases, usually no synchronous PDOs are transmitted via the system bus

(CANopen) anymore.