Page 160: Implemented canopen objects
E94AYCCA communication manual (CANopen®)
Implemented CANopen objects
160
L
EDS94AYCCA EN 5.0 - 06/2012
I-1011 - Restore default parameters
Load Lenze setting.
Corresponds to the device command C00002 = "0: Load Lenze setting".
This command serves to reset the parameters of the active application to the Lenze
setting which is stored in the firmware.
Read subindex 1
[14-5] Assignment of the data telegram (read )
Write subindex 1
In addition to the index and subindex, the telegram data must include the "load" signature
(ASCII characters; ISO 8859) so that the Lenze setting can be loaded.
Writing with a wrong identifier causes a response according to the CANopen
specification DS301, V4.02.
[14-6] Assignment of the data telegram (write)
Index:
I-1011
Name:
Restore default parameters
Subindex
Default setting
Setting range (min. value | unit | max. value)
Access
Data type
0: highest subindex supported
1
- (only read access)
ro
U32
1: restore all default parameters
-
0
4294967295 rw
U32
Subindex
Meaning
Read
Write
0
Max. supported subindex: 1
-
(A write attempt triggers the error
message 0x06010002.)
1
Loading of all parameters possible.
Load Lenze setting.
8th byte
7th byte
6th byte
5th byte
Data 4
Data 3
Data 2
Data 1
Bit 31 ... bit 1
Bit 0
0
0/1
Bit
Setting
Bit 0
0 Parameters cannot be loaded.
1 Parameters can be loaded (Lenze).
8th byte
7th byte
6th byte
5th byte
Data 4
Data 3
Data 2
Data 1
"d" = 0x64
"a" = 0x61
"o" = 0x6F
"l" = 0x6C