beautypg.com

1 parameter setting, Parameter setting, E94aycca communication manual (canopen®) – Lenze E94AYCCA User Manual

Page 51

background image

EDS94AYCCA EN 5.0 - 06/2012

L

51

E94AYCCA communication manual (CANopen®)

Process data transfer

Synchronisation of PDOs via sync telegram

8.4.1

Parameter setting

Short overview: Parameters for synchronisation via sync telegram

Sync source

C01120

is used to select the source of the synchronisation signals. Basically, only one

source can synchronise the node.

Sync cycle time
Time with which the internal phase-locking loop (PLL) expects the synchronisation signals.

The time must be set in

C01121

in accordance with the cycle of the synchronisation source

selected in

C01120

.

Example: For the system bus (CANopen), the interval between two synchronisation signals

has been set to 2 ms. If the system bus (CANopen) is to be used as synchronisation source,

a sync cycle time of 2000 μs must be set in

C01121

.

Parameter

Information

Lenze setting

Assignment

Value Unit

Sync

Master

Sync

Slave

C13367

C14367

CAN SYNC Rx identifier

128

z

C13368

C14368

CAN SYNC Tx identifier

128

z

C00369/1

CAN SYNC transmit cycle time

0 ms

z

C01120

Sync source

Off

z

C01121

Sync cycle time

1000 μs

z

C01122

Sync phase position

400 μs

z

C01123

Sync tolerance

0 μs

z

C01124

Sync-PLL increment

109 ns

z

C01130

Sync application cycle

1000 μs

z

Note!

For synchronisation via the system bus (CANopen), only integer multiples of

1000 μs should be set in

C01121

.