C13377

C13378

C13381

C13382

Parameter | Name:

C13377 | CAN SDO server node address

Data type: UNSIGNED_8

Index: 11198

d

= 2BBE

h

Node address of the server with which this client communicates via the client channel selected.

• An activation of the client functionality is not required.

• An entry is required so that the CAN-SDO client channel can be activated (see DS301, V4.02).
Setting range

(min. value | unit | max. value)

1

127

Subcodes

Lenze setting

Information

C13377/1

1

Remote server node address for SDO client channel 1 ...

10

...
C13377/10

;

Read access ; Write access … CINH … PLC STOP … No transfer

Scaling factor: 1

Parameter | Name:

C13378 | CAN delay boot-up - Operational

Data type: UNSIGNED_16

Index: 11197

d

= 2BBD

h

Time that has to elapse after mains switching before the CAN NMT master transmits the "Start remote node"

telegram on the bus.

• This time is only used after mains switching if the master bit is activated (

C13352

).

Setting range

(min. value | unit | max. value)

Lenze setting

0

ms

65535 3000 ms

;

Read access ; Write access … CINH … PLC STOP … No transfer

Scaling factor: 1

Parameter | Name:

C13381 | CAN Heartbeat Producer Time

Data type: UNSIGNED_16

Index: 11194

d

= 2BBA

h

Time interval for the transmission of the heartbeat telegram to one or several consumers.

• The parameterised time is rounded down to an integer multiple of 5 ms.

• The heartbeat telegram is transmitted automatically as soon as a time > 0 ms is set. The monitoring function

"Node Guarding" is deactivated in this case.

• Mapping of the CANopen object

I-1017

(see DS301, V4.02).

Heartbeat protocol ( 80)

Setting range

(min. value | unit | max. value)

Lenze setting

0

ms

65535 0 ms

;

Read access ; Write access … CINH … PLC STOP … No transfer

Scaling factor: 1

Parameter | Name:

C13382 | CAN Guard Time

Data type: UNSIGNED_16

Index: 11193

d

= 2BB9

h

• After the guard time (set here) multiplied with the life time factor (

C13383

), a node guarding telegram must

have arrived.

• Mapping of the CANopen object

I-100C

(see DS301, V4.02).

Node guarding protocol ( 74)

Setting range

(min. value | unit | max. value)

Lenze setting

0

ms

65535 0 ms

;

Read access ; Write access … CINH … PLC STOP … No transfer

Scaling factor: 1