E84aycer communication manual (profinet), Parameter reference table of attributes, Table of attributes – Lenze E84AYCER User Manual
Page 90
E84AYCER communication manual (PROFINET)
Parameter reference
Table of attributes
90
L
EDS84AYCER EN 2.0 - 11/2010
Table of attributes
Code
Name
Index
Data
Access
dec
hex
DS
DA
Data type
Factor
R
W
CINH
IP address
11575
2D37
E
1
UNSIGNED_32
1
;
;
Subnetwork mask
11574
2D36
E
1
UNSIGNED_32
1
;
;
Gateway address
11573
2D35
E
1
UNSIGNED_32
1
;
;
Physical address
11572
2D34
A
3
OCTET_STRING
;
Active IP address
11565
2D2D
A
4
UNSIGNED_8
1
;
Active subnetwork mask
11564
2D2C
A
4
UNSIGNED_8
1
;
Active IP address
11563
2D2B
A
4
UNSIGNED_8
1
;
All words to master
10725
29E5
A
16
UNSIGNED_16
1
;
All words from master
10724
29E4
A
16
UNSIGNED_16
1
;
All words to standard device
10723
29E3
A
16
UNSIGNED_16
1
;
All words from standard device
10722
29E2
A
16
UNSIGNED_16
1
;
Settings
10715
29DB
A
4
UNSIGNED_8
1
;
Bus status
10714
29DA
E
1
BITFIELD_16
;
Bus counter
10713
29D9
A
3
UNSIGNED_32
1
;
Active station name
10711
29D7
A
8
VISIBLE_STRING
;
Display: Most recent diagnostic data
10708
29D4
E
1
OCTET_STRING
;
Bus error(1)
10698
29CA
E
1
UNSIGNED_16
1
;
Bus error(2)
10697
29C9
E
1
BITFIELD_16
;
Reaction on communication failure
10695
29C7
A
1
UNSIGNED_8
1
;
;
Reaction time delay
10694
29C6
E
1
UNSIGNED_16
1
;
;
Clear process data
10690
29C2
E
1
UNSIGNED_8
1
;
;
Suppress signalling diag. mess. upon
10688
29C0
E
1
BITFIELD_8
;
;
Station name
10676
29B4
A
8
VISIBLE_STRING
;
;
Firmware product type
10675
29B3
E
1
VISIBLE_STRING
;
Firmware compilation date
10674
29B2
E
1
VISIBLE_STRING
;
Firmware version
10673
29B1
E
1
VISIBLE_STRING
;
I&M1 system designation
10665
29A9
E
1
VISIBLE_STRING
;
;
I&M1 installation site
10664
29A8
E
1
VISIBLE_STRING
;
;
I&M2 installation date
10663
29A7
E
1
VISIBLE_STRING
;
;
I&M3 additional information
10662
29A6
A
2
VISIBLE_STRING
;
;
I&M4 signature code
10661
29A5
A
2
OCTET_STRING
;
;