Safety instructions
Device- and application-specific safety instructions
2.2
Device- and application-specific safety instructions
During operation, the communication module must be securely connected to the
standard device.
Use a safely separated power supply unit in accordance with EN 61800-5-1 ("SELV"/
"PELV").
Only use cables that meet the listed specifications.
Specification of the Ethernet cable
2.3
Residual hazards
Protection of persons
If the Inverter Drives 8400 are used on a phase earthed mains with a rated mains
voltage ≥ 400 V, external measures need to be implemented in order to provide reliable
protection against accidental contact.
Device protection
The communication module contains electronic components that can be damaged or
destroyed by electrostatic discharge.
Documentation for the standard device, control system, plant/machine
All the other measures prescribed in this documentation must also be
implemented. Observe the safety instructions and application notes contained
in this manual.