beautypg.com

12 error messages, Error messages, E84aycer communication manual (profinet) – Lenze E84AYCER User Manual

Page 73

background image

EDS84AYCER EN 2.0 - 11/2010

L

73

E84AYCER communication manual (PROFINET)

Error messages

Short overview (A-Z) of the PROFINET error messages

12

Error messages

This chapter provides the error messages of the communication module as a supplement

to the error list in the software manual and the »Engineer« online help for the Inverter

Drive 8400.

12.1

Short overview (A-Z) of the PROFINET error messages

The following table contains all error messages of the communication module in

alphabetical order with the preset error response and, if available, the parameter for

setting the error response.

Tip!
When you click the cross-reference in the last column, you will get a detailed

description (causes and remedies) of the corresponding error message.

Software manual/»Engineer« online help for the Inverter Drive 8400
General information on diagnostics & fault analysis and error messages is

provided here.

Error text

Error type

Subject area

no.

Error no.

Adjustable

in

Detailed

information

PROFINET: Data_Exchange status quit

0: None

444

25905

C13880/1

0x01bc6531

PROFINET: Error: Lenze setting loaded

1: Fault

444

25632

-

0x01bc6420

PROFINET: Exist. connect. to 8400 lost

1: Fault

444

12544

-

0x01bc3100

PROFINET: Internal error

1: Fault

444

24593

-

0x01bc6011

PROFINET: Internal error

1: Fault

444

24832

-

0x01bc6100

PROFINET: Internal error

1: Fault

444

24833

-

0x01bc6101

PROFINET: Internal error

1: Fault

444

26192

-

0x01bc6650

PROFINET: Invalid module configuration

1: Fault

444

25648

-

0x01bc6430

PROFINET: Invalid output data

4: Warning locked

444

25859

-

0x01bc6503

PROFINET: Invalid parameter set

1: Fault

444

25631

-

0x01bc641f

PROFINET: IP address error

1: Fault

444

25907

-

0x01bc6533

PROFINET: Memory: No access

1: Fault

444

21809

-

0x01bc5531

PROFINET: Memory: Read error

1: Fault

444

21810

-

0x01bc5532

PROFINET: Memory: Write error

1: Fault

444

21811

-

0x01bc5533

PROFINET: Restart by watchdogreset

1: Fault

444

24592

-

0x01bc6010

PROFINET: Stack init error

1: Fault

444

25908

-

0x01bc6534

PROFINET: Station name error

1: Fault

444

25906

-

0x01bc6532

PROFINET: Record parameter: Invalid read

4: Warning locked

444

25857

-

0x01bc6501

PROFINET: Record parameter: Invalid write

4: Warning locked

444

25858

-

0x01bc6502