Page 89: Parameter reference table of attributes
EDS84AYCER EN 2.0 - 11/2010
L
89
E84AYCER communication manual (PROFINET)
Parameter reference
Table of attributes
13.2
Table of attributes
The table of attributes contains information which is required for communicating with the
controller via parameters.
How to read the table of attributes:
Column
Meaning
Entry
Code
Parameter name
Cxxxxx
Name
Parameter short text (display text)
Text
Index
dec
Index by which the parameter is addressed.
The subindex for array variables corresponds to the
Lenze subcode number.
24575 - Lenze code number
Only required for access via bus
system.
hex
5FFF
h
- Lenze code number
Data
DS
Data structure
E
Single variable
(only one parameter element)
A
Array variable
(several parameter elements)
DA
Number of array elements (subcodes)
Number
DT
Data type
BITFIELD_8
1 byte, bit-coded
BITFIELD_16
2 bytes, bit-coded
BITFIELD_32
4 bytes, bit-coded
INTEGER_8
1 byte with sign
INTEGER_16
2 bytes with sign
INTEGER_32
4 bytes with sign
UNSIGNED_8
1 byte without sign
UNSIGNED_16
2 bytes without sign
UNSIGNED_32
4 bytes without sign
VISIBLE_STRING
ASCII string
OCTET_STRING
Factor
Factor for data transmission via a bus system,
depending on the number of decimal positions
Factor
1 ≡ no decimal positions
10 ≡ 1 decimal position
100 ≡ 2 decimal positions
1000 ≡ 3 decimal positions
Access
R
Read access
;
Reading permitted
W
Write access
;
Writing permitted
CINH
Controller inhibit required
;
Writing is only possible when the controller is inhibited