E84AYCER communication manual (PROFINET)

Parameter reference

Parameters of the communication module

86

L

EDS84AYCER EN 2.0 - 11/2010

C13885

C13887

C13899

Parameter | Name:

C13885 | Clear process data

Data type: UNSIGNED_8

Index: 10690

d

= 29C2

h

This code is used to set the process data that are to be processed by the IO device in order to maintain internal

communication when the PROFINET has left the DATA_EXCHANGE status.
Selection list

(Lenze setting printed in bold)

Information

0 Use of most recent master PDOs

The last data sent by the IO controller are used.

1 PDOs are set to the value'0'

The contents of the process data are set to the value "0".

;

Read access ; Write access … CINH … PLC-STOP … No transfer … PDO_MAP_RX … PDO_MAP_TX … COM … MOT

Parameter | Name:

C13887 | Suppress signalling diag. mess. upon

Data type: BITFIELD_8

Index: 10688

d

= 29C0

h

This code serves to inhibit the transmission of alarm messages to the IO controller. By this, errors of a specific type

can be systematically suppressed. All errors are furthermore entered in the logbook.

• A change will only become effective immediately if no error number with the error type selected here is pending

in C00165.

Value is bit-coded:

Information

Bit 0 Fault
Bit 1 Trouble
Bit 2 Quick stop by trouble
Bit 3 Warning locked
Bit 4 Warning
Bit 5 Reserved
Bit 6 Reserved
Bit 7 Reserved

;

Read access ; Write access … CINH … PLC-STOP … No transfer … PDO_MAP_RX … PDO_MAP_TX … COM … MOT

Parameter | Name:

C13899 | Station name

Data type: VISIBLE_STRING

Index: 10676

d

= 29B4

h

The name with a max. length of 240 characters is distributed to the subindices. The name can be entered starting

with subindex 1. The following unused subindices are not relevant.

• The station name must be assigned in accordance with the PROFINET specification. In the standard setting a

deleted name is displayed. The name is also deleted if the "Reset to factory defaults" command is executed by an

IO supervisor or an IO controller.

• A change of the station name will only become effective by switching the mains of the controller.

Setting the station name ( 36)

Subcodes

Lenze setting

Information

C13899/1

1st ... 30th character

C13899/2

31st ... 60th character

C13899/3

61st ... 90th character

C13899/4

91st ... 120th character

C13899/5

121st ... 150th character

C13899/6

151st ... 180th character

C13899/7

181st ... 210th character

C13899/8

211th ... 240th character

;

Read access ; Write access … CINH … PLC-STOP … No transfer … PDO_MAP_RX … PDO_MAP_TX … COM … MOT