4 error information (error), Error information (error), E84aycer communication manual (profinet) – Lenze E84AYCER User Manual
Page 62: Parameter data transfer error information (error)
E84AYCER communication manual (PROFINET)
Parameter data transfer
Error information (error)
62
L
EDS84AYCER EN 2.0 - 11/2010
9.4
Error information (error)
Error code
Meaning
Description
Additional
information
0x0000
Impermissible parameter
number
Access to unavailable parameter
-
0x0001
Parameter value cannot be
changed
Change access to a parameter value that cannot be
changed
Subindex
0x0002
Lower or upper value limit
exceeded
Change access with value outside the value limits
Subindex
0x0003
Faulty subindex
Access to unavailable subindex
Subindex
0x0004
No array
Access with subindex to non-indexed parameter
-
0x0005
Incorrect data type
Change access with value that does not match the
data type of the parameter
-
0x0006
Setting not permitted (can
only be reset)
Change access with non-zero value where this is not
permitted
Subindex
0x0007
Description element cannot
be changed
Change access to a description element that cannot
be changed
Subindex
0x0008
Reserved
(PROFIdrive profile V2: PPO-Write requested in IR is
not available)
-
0x0009
No description data available Access to unavailable description (parameter value is
available)
-
0x000A
Reserved
(PROFIdrive profile V2: Wrong access group)
-
0x000B
No parameter change rights Change access without parameter change rights
-
0x000C
Reserved
(PROFIdrive profile V2: Wrong password)
-
0x000D
Reserved
(PROFIdrive profile V2: Text cannot be read in cyclic
data transfer)
-
0x000E
Reserved
(PROFIdrive profile V2: Name cannot be read in cyclic
data transfer)
-
0x000F
No text array available
Access to unavailable text array (parameter value is
available)
-
0x0010
Reserved
(PROFIdrive profile V2: No PPO-Write)
-
0x0011
Request cannot be executed
because of operating state
Access is not possible for temporary reasons that are
not specified in detail
-
0x0012
Reserved
(PROFIdrive profile V2: Other error)
-
0x0013
Reserved
(PROFIdrive profile V2: Date cannot be read in cyclic
data transfer)
-
0x0014
Impermissible value
Change access with a value that is within the value
limits but is not permissible for other permanent
reasons (parameter with defined single values)
Subindex
0x0015
Response too long
The length of the current response exceeds the
maximum transmittable length
-
0x0016
Impermissible parameter
address
Impermissible value or value which is not supported
for the attribute, number of subindexes, parameter
number, or subindex, or a combination
-
0x0017
Impermissible format
Write request: Impermissible parameter data format
or parameter data format which is not supported
-
0x0018
Number of values not
consistent
Write request: Number of parameter data values
does not match the number of subindexes in the
parameter address
-
0x0019
Reserved
-
-
...
0x0064