Commissioning

Setting the IP configuration

38

L

EDS84AYCER EN 2.0 - 11/2010

6.4

Setting the IP configuration

If the communication module is to be made accessible via its IP parameters, the IP address,

subnet mask, and gateway address must either be assigned by the IO controller via

PROFINET or set manually in the »Engineer«.
In the »Engineer« the IP parameters are set under the Settings tab.

Note!

• The IP parameters are written to codes

C13000

(IP address),

C13001

(subnet

mask), and

C13002

(gateway address) as decimal values.

Use the [ int ] buttons to the right of the input fields to change to the decimal

code representation.

• The assignment of invalid combinations of IP address, subnet mask, and

gateway address can have the consequence that no connection to the

PROFINET can be established.

• In the case of impermissible settings the red LED "BE" (

Fieldbus status displays

( 68)

) blinks.

• If the IP parameters are assigned by the IO controller via PROFINET the change

is activated immediately. The current parameter values are displayed in the

corresponding codes.