E84AYCER communication manual (PROFINET)

Data transfer

7

Data transfer

PROFINET transmits parameter data, configuration data, diagnostic data, alarm messages,

and process data between the host system (IO controller) and the controllers that are part

of the fieldbus (IO devices). Depending on their time-critical behaviour, the data are

transmitted via corresponding communication channels.

Communication channels

 The process data channel transmits process data.

– With the process data the controller is actuated.
– The transmission of process data is time-critical.
– Process data are transmitted cyclically between the IO controller and the IO devices

that are part of the fieldbus according to the Provider/Consumer model (continuous

exchange of current input and output data).

– The IO controller can directly access the process data. In the PLC, for instance, the

data are directly assigned to the IO area.

– In the case of Inverter Drives 8400 protec maximally 16 process data words (16 bits/

word) can be exchanged for each direction.

– Process data are not stored in the Inverter Drive 8400 protec.
– Process data are e.g. setpoints, actual values, control and status words.

 Parameter data are transmitted via the acyclic channel.

– Usually the transmission of parameter data is not time-critical.
– The access to the parameter data depends on the PROFIdrive profile.
– Examples of parameter data are operating parameters, motor data, and diagnostic

information.

– The acyclic channel provides access to all Lenze codes.
– Parameter changes must be saved via code C00002 of the Inverter Drives 8400

protec.

Note!

Please observe the direction of the flow of information!
• Process input data (Rx data):

– Process data from the controller (IO device) to the IO controller

• Process output data (Tx data):

– Process data from the IO controller to the controller (IO device)