6 transmitter display, 1 operational mode, 1 system start – CiDRA SONARtrac PW VF-100 User Manual
Page 108: Transmitter display -14, Operational mode -14, System start -14, Figure 13, Startup screen -14

20833-01 Rev 04
Page 7-14
7.6
Transmitter Display
The transmitter display functions in two distinct modes: an operational
mode and a menu mode. These two modes will be explained in the
following sections.
7.6.1
Operational Mode
The transmitter screen displays the status of the passive sonar meter
system. A few typical screen messages and their interpretation follow.
7.6.1.1
System Start
The transmitter displays the startup progress as it loads firmware into
various parts of the system and the Ethernet IP address of the
transmitter as it starts up. Once startup is complete, the display will
clear and begin displaying measurements. Full system startup is
discussed in Section 10.
Figure 13
Startup Screen
If internal configuration parameters are changed in the menu screens
once the menu is exited, the display will clear and show the ‘Startup
>>>>’ display. This indicates that the system is restarting with the
new parameters and is beginning to make measurements. Flow
measurements will be displayed when the startup procedure is
complete.
Startup >>>>>>>>>>>>>
010.001.009.13
4
D 01.02.10 P 01.00.14 VF /
System is
starting
Firmware
revisions as
they load:
I: Interface
F: FPGA
D: DSP
P: PreAmp
A: USB or
Alchemy
S: Softing or
Fieldbus
Ethernet
IP Address
Mode and
heartbeat