Figure 19, Fiberglass cover -23, Warning – CiDRA SONARtrac PW VF-100 User Manual
Page 41

20831-01 Rev 05
Page 5-23
The passive sonar sensor head cover is illustrated in the following
figure.
Figure 19 Fiberglass Cover
WARNING
The handles on the cover are designed for holding the cover in
place during installation. The handles are not designed or rated
for hoisting the cover. Use a proper lifting sling to properly
secure cover to lifting rope when hoisting cover.
Each pipe size has a cover designed to fit that size pipe.
The cover incorporates a connector assembly for the sensor head to
transmitter cable, a breather valve, interlocking thermo-plastic elastic
(TPE) seals along the cover longitudinal edges, and a radial boot seal
at the ends of the cover that seal the cover to the pipe using stainless
steel band clamps. Tool operated latches and keepers are used to
hold the cover halves together.
Connector
Access
cover
Breather
vent
Handle
Boot seal
Edge seal
TPE rubber
Latch and
keeper