4 sensor band thermal barrier installation, Sensor band thermal barrier installation -19, Figure 14 – CiDRA SONARtrac PW VF-100 User Manual
Page 37: Thermal barrier installation over sensor band -19

20831-01 Rev 05
Page 5-19
5.6.4
Sensor Band Thermal Barrier Installation
Install the sensor band thermal barrier if one was included with the
System. Refer to the figure below.
1. Align the slit on the thermal barrier with the sensor band to pre-
amplifier cable.
2. Wrap the thermal barrier over the sensor attachment rails.
3. Continue to wrap the thermal barrier around the sensor band.
4. Seal at the Velcro strips and install the straps through the D-rings
on the thermal barrier.
5. Retain the sensor band to pre-amplifier cable in the Velcro
retention loop.
Figure 14 Thermal Barrier Installation Over Sensor Band
Mounting rails on top of
pipe covered with
thermal barrier
Velcro strip for sealing
thermal barrier
Sensor band to pre-
amplifier cable in slot on
thermal barrier
Sensor band to pre-
amplifier cable in
retention loop
Thermal barrier
straps (both sides)