5 keypad, Keypad -13, Figure 12 – CiDRA SONARtrac PW VF-100 User Manual
Page 107: Transmitter front panel keyboard -13, Table 1, Keypad functions in operational and menu modes -13

20833-01 Rev 04
Page 7-13
7.5
Keypad
The keypad controls used to set up and access the user input screens
are illustrated in the following figure.
Figure 12
Transmitter Front Panel Keyboard
The passive sonar meter display has 2 distinct modes: the
operational mode where the measured parameters are displayed
and the menu mode where various system parameters can be set. In
each of these modes the keypad will have different functions. The
following table shows the function of each key in the keypad
depending on the display mode. Menu traversal rules are based on
the following table.
Key
Operational
Mode
Menu Mode
Dialog
Box
Navigation
Editing
Up
Enter Menu
Mode
Cycle Menu Item
Change current value at
cursor position
Exit Dialog
Down
Enter Menu
Mode
Cycle Menu Item
Change current value at
cursor position
Exit Dialog
Left
Enter Menu
Mode
NA
Change cursor position
Exit Dialog
Right
Enter Menu
Mode
NA
Change cursor position
Exit Dialog
EXIT
Clears Alarm
Exit Menu
Exit Menu
Exit Dialog
BACK
Enter Menu
Mode
Exit Menu from Main
Menu or back up one
level in menu tree
Exit editing mode
without saving
Exit Dialog
ENTER
Enter Menu
Mode
Change menu level or
start editing
Exit editing mode and
save current value
Exit Dialog
Table 1