Hitless layer 2 os upgrade, Upgrading the mbridge fpga image – Brocade BigIron RX Series Hardware Reference Manual User Manual

Page 153

background image

Brocade BigIron RX Series Hardware Installation Guide

141

53-1002483-03

Upgrading images independently

6

.

SL M1: RX-BI-MR Management Module Standby (Serial #: SA36060509, Part #:

35524-000B):

Boot : Version 2.7.3T145 Copyright (c) 1996-2010 Brocade Communications

Systems, Inc.

Compiled on Jun 12 2010 at 01:44:54 labeled as rmb02703b394

(439602 bytes) from boot flash

Monitor : Version 2.7.3T145 Copyright (c) 1996-2010 Brocade Communications

Systems, Inc.

Compiled on Jul 9 2010 at 09:35:50 labeled as rmb02703b413

(439602 bytes) from code flash

IronWare : Version 2.7.3T143 Copyright (c) 1996-2010 Brocade Communications

Systems, Inc.

Compiled on Jul 9 2010 at 09:41:14 labeled as rmpr02703b413

(4528285 bytes) from Primary

Board ID : 00 MBRIDGE Revision : 21

916 MHz Power PC processor (version 8003/0101) 166 MHz bus

512 KB Boot Flash (AM29LV040B), 32 MB Code Flash (MT28F128J3)

512 MB DRAM

Standby Management uptime is 12 days 2 hours 51 minutes 45 seconds

.

.

.

The output indicates that the management module currently has MBRIDGE Revision: 21 installed.

Upgrading the MBRIDGE FPGA image

Follow the steps given below to upgrade one or more MBRIDGE FPGA images on a BigIron RX
Series management module.

1. Place the new MBRIDGE FPGA image on a TFTP server to which the BigIron RX Series system

has access or on a PCMCIA flash card inserted in slot 1 or 2.

2. Copy the MBRIDGE FPGA image from the TFTP server or a flash card in slot 1 or 2 to all

management modules or a management module in a specified chassis slot. To perform this
step, enter one of the following commands at the Privileged EXEC level of the CLI (example:
BigIron RX

#

):

copy tftp mbridge <ip-addr> <image-name> MBRIDGE

copy slot1 | slot2 mbridge <image-name> MBRIDGE

3. After the MBRIDGE upgrade is complete, the management module must be power-cycled.

4. Verify that the MBRIDGE images have been successfully copied to the specified interface

modules by entering the following command at any level of the CLI:

show version

Check for the MBRIDGE image version numbers in the output.

Hitless Layer 2 OS upgrade

Version 02.3.00a and later of the Multi-Service IronWare software support hitless upgrade of the
operating system on a BigIron RX switch.