beautypg.com

Physical dimensions, Operating environment, Storage environment – Brocade BigIron RX Series Hardware Reference Manual User Manual

Page 171: Safety agency approvals

background image

Brocade BigIron RX Series Hardware Installation Guide

159

53-1002483-03

Hardware specifications

7

NOTE

The DC input PSU has a -40VDC to -60VDC operating range with -48VDC as the nominal input
voltage.

Physical dimensions

Table 33

provides the physical dimensions for the BigIron RX Series chassis.

Operating environment

Table 34

provides the operating environment specifications for the BigIron RX Series chassis.

Storage environment

Table 35

provides the storage environment specifications for the BigIron RX Series chassis.

Safety agency approvals

CAN/CSA-C22.2 No. 60950-1-03/UL60950-1 – Third Edition, Safety of Information Technology
Equipment

EN 60825-1 Safety of Laser Products – Part 1: Equipment Classification, Requirements and
User’s Guide

EN 60825-2 Safety of Laser Products – Part 2: Safety of Optical Fibre Communications
Systems

EN 60950-1:2001\IEC 60950-1 Safety of Information Technology Equipment

TABLE 33

BigIron RX Series physical dimensions

BigIron RX Series
chassis

Height

Width

Depth

Weight (fully loaded)

BigIron RX-4

17.7 cm (6.96 in.)

44.3 cm (17.45 in.)

52.1 cm (20.53 in.)

35 kg (78 lbs)

BigIron RX-8

31 cm (12.21 in.)

44.3 cm (17.45 in.)

53.3 cm (21 in.)

60 kg (131 lbs)

BigIron RX-16

62.2 cm (24.47 in.)

43.7 cm (17.2 in.)

63.5 cm (25 in.)

107 kg (236 lbs)

TABLE 34

BigIron RX Series operating environment

Operating temperature

Relative humidity

Operating altitude

0

– 40

C (32

– 104

F)

5 to 90

, at 40



C (104

F),

non-condensing

0 – 2012 meters (0 – 6600 ft)

TABLE 35

BigIron RX series storage environment

Storage temperature

Storage humidity

Storage altitude

-25



– 70



C (-13



158



F)

95

maximum relative humidity,

non-condensing

(0 – 4500 meters (0 – 15,000 ft)