Physical dimensions, Operating environment, Storage environment – Brocade BigIron RX Series Hardware Reference Manual User Manual
Page 171: Safety agency approvals
![background image](/manuals/52384/171/background.png)
Brocade BigIron RX Series Hardware Installation Guide
159
53-1002483-03
Hardware specifications
7
NOTE
The DC input PSU has a -40VDC to -60VDC operating range with -48VDC as the nominal input
voltage.
Physical dimensions
provides the physical dimensions for the BigIron RX Series chassis.
Operating environment
provides the operating environment specifications for the BigIron RX Series chassis.
Storage environment
provides the storage environment specifications for the BigIron RX Series chassis.
Safety agency approvals
•
CAN/CSA-C22.2 No. 60950-1-03/UL60950-1 – Third Edition, Safety of Information Technology
Equipment
•
EN 60825-1 Safety of Laser Products – Part 1: Equipment Classification, Requirements and
User’s Guide
•
EN 60825-2 Safety of Laser Products – Part 2: Safety of Optical Fibre Communications
Systems
•
EN 60950-1:2001\IEC 60950-1 Safety of Information Technology Equipment
TABLE 33
BigIron RX Series physical dimensions
BigIron RX Series
chassis
Height
Width
Depth
Weight (fully loaded)
BigIron RX-4
17.7 cm (6.96 in.)
44.3 cm (17.45 in.)
52.1 cm (20.53 in.)
35 kg (78 lbs)
BigIron RX-8
31 cm (12.21 in.)
44.3 cm (17.45 in.)
53.3 cm (21 in.)
60 kg (131 lbs)
BigIron RX-16
62.2 cm (24.47 in.)
43.7 cm (17.2 in.)
63.5 cm (25 in.)
107 kg (236 lbs)
TABLE 34
BigIron RX Series operating environment
Operating temperature
Relative humidity
Operating altitude
0
– 40
C (32
– 104
F)
5 to 90
, at 40
C (104
F),
non-condensing
0 – 2012 meters (0 – 6600 ft)
TABLE 35
BigIron RX series storage environment
Storage temperature
Storage humidity
Storage altitude
-25
– 70
C (-13
–
158
F)
95
maximum relative humidity,
non-condensing
(0 – 4500 meters (0 – 15,000 ft)