Upgrading images independently

6

4. If you want to upgrade other software images, go to the appropriate upgrade section for
information. If you have completed upgrading the software images, you must reboot the
management module to complete the upgrade process. For more information,refer to

“Rebooting the management module”

on page 139.

Upgrading the IronWare image on a management module

To upgrade the management module IronWare image (primary or secondary), you must perform
the following steps:

1. Place the new IronWare image on a TFTP server to which the BigIron RX system has access or

on a PCMCIA flash card inserted in slot 1 or 2.

2. Copy the new IronWare image from the TFTP server or a flash card in slot 1 or 2 to the

management module's code flash or a flash card in slot 1 or 2.

To perform this step, enter one of the following commands at the Privileged EXEC level of the
CLI:

copy tftp flash <TFTP-server-ip-addr> <image-name> primary | secondary

copy tftp slot1 | slot2 <TFTP-server-ip-addr> <image-name> primary | secondary

copy slot1 | slot2 flash <image-name> primary | secondary

copy slot1 | slot2 slot1 | slot2 <image-name> <dest-name>

For example, to copy the management module's Ironware image from TFTP server
10.10.12.12, enter

BigIron RX# copy tftp flash 10.10.12.12 rmpr02702h.bin primary

3. Verify that the new IronWare image has been successfully copied to the specified destination

by entering one of the following commands at the Privileged EXEC level of the CLI:

show flash (if the destination was code flash)

dir /<path-name>/ (if the destination was slot 1 or 2)

4. Check for the primary or secondary images and the date and time that it was placed in the

directory.

5. If you want to upgrade other software images, go to the appropriate upgrade section for

information. If you have completed upgrading the software images, you must reboot the
management module to complete the upgrade process. For more information, see Rebooting
the management module. For more information, refer to

“Rebooting the management module”

on page 139.

Upgrading the monitor and boot images on interface modules

NOTE

We recommend that you perform this upgrade procedure from a PC or terminal that is directly
connected to the management module’s Console port. You can also perform this procedure through
a Telnet or SSHv2 session.