Specifying an immediate boot from a tftp server – Brocade BigIron RX Series Hardware Reference Manual User Manual
Page 104

92
Brocade BigIron RX Series Hardware Installation Guide
53-1002483-03
Managing the interface modules
4
The <slot-number> parameter specifies the BigIron RX chassis slot number that contains the 
interface module that will undergo an immediate boot. You can specify 1 – 4 for BigIron RX-4, 1 – 8 
for BigIron RX-8 or 1 – 16 for BigIron RX-16.
Specifying an immediate boot from the management module’s flash memory
For example, to specify an immediate boot from the primary IronWare image in the management 
module’s flash memory for the interface module installed in slot 1, enter the following command at 
the Privileged EXEC level of the CLI:
BigIron RX# lp boot system mp primary 1
Syntax: lp boot system mp primary | secondary <slot-number>
The primary and secondary keywords specify the primary or secondary IronWare image in the 
management module’s flash memory.
The <slot-number> parameter specifies the BigIron RX Series chassis slot number that contains 
the interface module that will undergo an immediate boot. You can specify 1 – 4 for BigIron RX-4, 1 
– 8 for BigIron RX-8 or 1 – 16 for BigIron RX-16.
Specifying an immediate boot from the interface module’s flash memory
For example, to specify an immediate boot from the primary IronWare image in the interface 
module’s flash memory for the interface module installed in slot 1, enter the following command at 
the Privileged EXEC level of the CLI:
BigIron RX# lp boot system flash primary 1
Syntax: lp boot system flash primary | secondary <slot-number>
The primary and secondary keywords specify the primary or secondary IronWare image in the 
interface module’s flash memory.
The <slot-number> parameter specifies the BigIron RX Series chassis slot number that contains 
the interface module that will undergo an immediate boot. You can specify 1 – 4 for BigIron RX-4, 1 
– 8 for BigIron RX-8 or 1 – 16 for BigIron RX-16.
Specifying an immediate boot from a TFTP server
For example, to specify an immediate boot for the interface module installed in slot 1 from a TFTP 
server, enter the following command at the Privileged EXEC level of the CLI:
BigIron RX# lp boot system tftp 123.123.123.123 primary 1
Syntax: lp boot system tftp <ip-address> <filename> <slot-number>
The <ip-address> parameter specifies the IP address of the TFTP server from which the interface 
module will be booted.
The <filename> parameter specifies the name of the image from which to boot the interface 
module.
The <slot-number> parameter specifies the BigIron RX Series chassis slot number that contains 
the interface module that will undergo an immediate boot. You can specify 1 – 4 for BigIron RX-4, 1 
– 8 for BigIron RX-8 or 1 – 16 for BigIron RX-16.