beautypg.com

Managing the interface modules, Displaying temperature warnings – Brocade BigIron RX Series Hardware Reference Manual User Manual

Page 100

background image

88

Brocade BigIron RX Series Hardware Installation Guide

53-1002483-03

Managing the interface modules

4

Syntax: show chassis

For information about all output generated by the show chassis command,refer to

“Displaying

chassis status and temperature readings”

on page 79.

Displaying temperature warnings

If the temperature of a module exceeds the high temperature threshold for any of the fan speeds,
the system sends a warning message to the system log and an SNMP trap. (For more information
about the low and high temperature thresholds, refer to

“Changing temperature thresholds for

modules and fan speeds”

on page 83.) This section describes how to view the system log. If you

have configured the BigIron RX Series system to use a Syslog server or SNMP trap receiver, refer to
the documentation for the server or receiver.

To display the system log, enter the following command at any CLI level:

Syntax: show log

Managing the interface modules

This section contains the following information:

Configuring interface module boot parameters

Changing the priority of chassis slots for interface modules

Disabling and reenabling power to the interface modules

TABLE 21

Fan status and speed fields

This field...

Displays...

Status

The status can be one of the following:

OK – The fan is functioning properly and is keeping the temperature of each module within
an acceptable temperature range.

Failed – The fan is not functioning properly or the fan control module cannot control the
fan.

Speed

The speed can be one of the following:

LOW – The fan is functioning at 50 percent of capacity

MEDIUM – The fan is functioning at 75 percent of capacity

MEDIUM-HIGH – The fan is functioning at 90 percent of capacity

HIGH – The fan is functioning at 100 percent of capacity

BigIron RX# show chassis

...

--- FANS ---

Right Fan Tray: Fan 5: Status = OK, Speed = LOW (50%) (RPM 3333)

Right Fan Tray: Fan 6: Status = OK, Speed = LOW (50%) (RPM 3488)...

BigIron RX# show log

Syslog logging: enabled (0 messages dropped, 0 flushes, 0 overruns)