Specifying an immediate interactive boot, Configuring an automatic boot – Brocade BigIron RX Series Hardware Reference Manual User Manual
Page 105

Brocade BigIron RX Series Hardware Installation Guide
93
53-1002483-03
Managing the interface modules
4
Specifying an immediate interactive boot
To specify an immediate interactive boot for the interface module installed in slot 1, enter the 
following command at the Privileged EXEC level of the CLI:
BigIron RX# lp boot system interactive 1
Syntax: lp boot system interactive <slot-number>
The 
the interface module that will undergo an immediate boot. You can specify 1 – 4 for BigIron RX-4, 1 
– 8 for BigIron RX-8 or 1 – 16 for BigIron RX-16.
After you enter this command, the system enters the interface module’s monitor mode. For 
example, to boot from the primary IronWare image in the interface module’s flash memory, enter 
the following command at the monitor prompt:
LP MONITOR> boot system flash primary
Configuring an automatic boot
You can configure an automatic boot for one or all interface modules from a specified source by 
entering the lp boot system command in the global CONFIG level. Provided that you save this 
configuration by entering the write memory command, the system will implement the automatic 
boot starting with the next software reload or system reset and each reload or reset after that.
Configuring an automatic boot from the management module’s PCMCIA slot
For example, to configure an automatic boot for all interface modules from the management 
module’s PCMCIA slot 1, enter the following command at the global CONFIG level of the CLI:
BigIron RX(config)# lp boot system slot1 primary all
Syntax: lp boot system slot1 | slot2 <filename> all | <slot-number>
The slot1 and slot2 keywords indicate the management module’s PCMCIA slot from which to boot 
the interface modules.
The <filename> parameter specifies the name of the image from which to boot the interface 
modules.
The all | <slot-number> parameter specifies that the automatic boot applies to all interface 
modules in the BigIron RX Series chassis or to an interface module in the specified chassis slot 
number only. You can specify 1 – 4 for BigIron RX-4, 1 – 8 for BigIron RX-8 or 1 – 16 for BigIron 
RX-16.
Configuring an automatic boot from the management module’s flash memory
For example, to configure an automatic boot from the primary IronWare image in the management 
module’s flash memory for all interface modules, enter the following command at the global 
CONFIG level of the CLI:
BigIron RX(config)# lp boot system mp primary all
Syntax: lp boot system mp primary | secondary all | <slot-number>
The primary and secondary keywords specify the primary or secondary IronWare image in the 
management module’s flash memory.