Sbx status leds, Table 13. sbx status leds – Allied Telesis SwitchBlade x3112 User Manual

Page 55

background image

SwitchBlade x3112 Installation Guide

55

SBx STATUS

LEDs

The SBx STATUS LEDs display general status information about the
Ethernet line cards and control cards. There is one LED for each slot. If the
chassis has two control cards, the SBx Status LEDs on both cards are
active. The states of the LEDs are defined in Table 13.

PSU

Solid Green

Indicates that the power supplies are operating
properly.

Flashing
Amber

Indicates that a power supply is experiencing a
problem. Possible causes are:

The input AC voltage from a power source is
not within the normal operating range of a
power supply module.

The output DC voltage from a power supply
module to the line cards is not within the
normal operating range.

A power supply is experiencing high
temperature.

A power supply has failed.

Check the status LEDs on the individual power
supply modules to determine which module has a
fault condition.

FAN

Solid Green

Indicates that the fan module is operating
properly.

Flashing
Amber

Indicates that the fan module has a problem. One
or more of the fans is operating below the normal
operating range or has stopped.

Table 12. SYS (System) Status LEDs (Continued)

LED

State

Description

Table 13. SBx STATUS LEDs

LEDs

State

Description

0 to 11

Off

Indicates that the slot is empty.

Solid Green

Indicates that the Ethernet line or control
card is operating normally.

Flashing Green

Indicates that the card is booting up, in test
mode, or loading the configuration settings.