SMBus Module and ACPI Block (Device 20, Function 0)
AMD SB600 Register Reference Manual
Proprietary
Page 112
SmartPowerControl2A - RW – 8 bits - [PCI_Reg: 98h]
Field Name
Bits
Default
Description
CheckLpc
0
0b
If SmartVoltEnable2 is set and this bit is also set, the
SmartPower2 function will only assert SmartVolt2 if LPC is idle
CheckAz
1
0b
If SmartVoltEnable2 is set and this bit is also set, the
SmartPower2 function will only assert SmartVolt2 if azalia (HD
audio) is idle
CheckAc97
2
0b
If SmartVoltEnable2 is set and this bit is also set, the
SmartPower2 function will only assert SmartVolt2 if AC97 is
idle
CheckPciBridge
3
0b
If SmartVoltEnable2 is set and this bit is also set, the
SmartPower2 function will only assert SmartVolt2 if azalia
PCIBridge is idle
CheckUsb
4
0b
If SmartVoltEnable2 is set and this bit is also set, the
SmartPower2 function will only assert SmartVolt2 if USBis idle
CheckSata
5
0b
If SmartVoltEnable2 is set and this bit is also set, the
SmartPower2 function will only assert SmartVolt2 if SATA is
idle
CheckIde
6
0b
If SmartVoltEnable2 is set and this bit is also set, the
SmartPower2 function will only assert SmartVolt2 if IDE is idle
CheckC3
7
0b
If SmartVoltEnable2 is set and this bit is also set, the
SmartPower2 function will only assert SmartVolt2 if CPU is in
C3 state
SmartPowerControl2A register
SmartPowerControl2B - RW – 8 bits - [PCI_Reg: 99h]
Field Name
Bits
Default
Description
CheckVIN0
0
0b
If SmartVoltEnable is set and this bit is also set, the
SmartPower function will only assert SmartVolt2 if VIN0 has
reached or passed the threshold
CheckVIN1
1
0b
If SmartVoltEnable is set and this bit is also set, the
SmartPower function will only assert SmartVolt2 if VIN1 has
reached or passed the threshold
CheckVIN2
2
0b
If SmartVoltEnable is set and this bit is also set, the
SmartPower function will only assert SmartVolt2 if VIN2 has
reached or passed the threshold
CheckVIN3
3
0b
If SmartVoltEnable is set and this bit is also set, the
SmartPower function will only assert SmartVolt2 if VIN3 has
reached or passed the threshold
CheckVIN4
4
0b
If SmartVoltEnable is set and this bit is also set, the
SmartPower function will only assert SmartVolt2 if VIN4 has
reached or passed the threshold
CheckVIN5
5
0b
If SmartVoltEnable is set and this bit is also set, the
SmartPower function will only assert SmartVolt2 if VIN5 has
reached or passed the threshold
CheckVIN6
6
0b
If SmartVoltEnable is set and this bit is also set, the
SmartPower function will only assert SmartVolt2 if VIN6 has
reached or passed the threshold
CheckVIN7
7
0b
If SmartVoltEnable is set and this bit is also set, the
SmartPower function will only assert SmartVolt2 if VIN7 has
reached or passed the threshold
SmartPowerControl2B register
SmartPowerControl2C - RW – 8 bits - [PCI_Reg: 9Ah]
Field Name
Bits
Default
Description
SmartVoltIdleTime2
6:0
0h
Amount of “idle” time (in 2us increment) the SmartPower2
function should wait before it should assert SmartVolt 2