The Cotton Picker Settings window contains fan speed sensor settings. To access this window, press the
Picker Settings button on the Picker Tab.

Cotton Picker Settings

Fan Speed Sensor Setting

Description

The Use Fan Speed checkbox specifies that the fan speed
must be running at a minimum of 2,500 RPM before data
logging will begin. This box is checked by default.

This setting can be unchecked if you are having

problems with the fan speed sensor. When unchecked,

the InSight monitor will not require a minimum fan

speed for logging data. Instead, it will log data anytime

the Master Button is on Auto.

The pulses per revolution (pls/rev) setting is the number of
pulses generated for one revolution of the fan, and is pre-
set for the factory-installed sensor on your machine. If you
replace a sensor, or believe the displayed fan speed to be
incorrect, you should verify this setting; and if necessary,
you can edit this number.