HP Insight Management for Tivoli User Manual
Page 90
![background image](/manuals/398556/90/background.png)
Appendix B: HP SNMP events 90
Trap types
Rules file
Description
Netcool
severity
sCellEventTrap-09-
cd(13602509)
13602509
This event occurs when a Fibre Channel
port transitions to the FAILED state.
Critical(5)
sCellEventTrap-09-
ce(13602510)
13602510
This event occurs when a Disk Group
transitions to an INOPERATIVE MARKED
state.
Clear (0)
sCellEventTrap-09-
cf(13602511)
13602511
This event occurs when a physical disk
drive transitions to the NOT PRESENT
state.
Minor(3)
sCellEventTrap-09-
d0(13602512)
13602512
This event occurs when an HSV300
controller no longer needs attention.
Clear (0)
sCellEventTrap-09-
d1(13602513)
13602513
This event occurs when an HSV300
controller needs attention.
Critical(5)
sCellEventTrap-09-
d2(13602514)
13602514
This event occurs when an HSV300
controller blower 1 is removed.
Critical(5)
sCellEventTrap-09-
d3(13602515)
13602515
This event occurs when at least one
Virtual Disk associated with a Data
Replication Group transitions to the
INOPERATIVE state. The remaining
Virtual Disks associated with this Data
Replication Group are forced to the
INOPERATIVE state.
Critical(5)
sCellEventTrap-09-
d4(13602516)
13602516
This event occurs when all the Virtual
Disks associated with a Data Replication
Group transition to the OPERATIVE state.
Clear (0)
sCellEventTrap-09-
d5(13602517)
13602517
This event occurs when the state of a
physical disk drive transitions to the
Single Port on Fibre state.
Clear (0)
sCellEventTrap-09-
d6(13602518)
13602518
This event occurs when an HSV300
controller powers off because the
temperature sensors do not agree and the
system temperature cannot be accurately
determined.
Minor(3)
sCellEventTrap-09-
d7(13602519)
13602519
This event occurs when an HSV300
controller powers off because the
temperature sensors cannot be accessed
and the system temperature cannot be
accurately determined.
Minor(3)
sCellEventTrap-09-
d8(13602520)
13602520
This event occurs when a Redundant
Storage Set has two members on the
same Fibre Channel device enclosure
causing a Disk Group to lose its Single
Point of Failure Robust Configuration.
Critical(5)
sCellEventTrap-09-
d9(13602521)
13602521
This event occurs when a Disk Group
attains a Single Point of Failure Robust
Configuration.
Clear (0)
sCellEventTrap-09-
da(13602522)
13602522
This event occurs when an HSV300
controller blower 1 is running at normal
speed.
Clear (0)
sCellEventTrap-09-
13602523
This event occurs when an HSV300
Clear (0)