Appendix B: HP SNMP events 90


Trap types

Rules file

Description

Netcool

severity

sCellEventTrap-09-
cd(13602509)

13602509

This event occurs when a Fibre Channel
port transitions to the FAILED state.

Critical(5)

sCellEventTrap-09-
ce(13602510)

13602510

This event occurs when a Disk Group
transitions to an INOPERATIVE MARKED

state.

Clear (0)

sCellEventTrap-09-

cf(13602511)

13602511

This event occurs when a physical disk

drive transitions to the NOT PRESENT
state.

Minor(3)

sCellEventTrap-09-
d0(13602512)

13602512

This event occurs when an HSV300
controller no longer needs attention.

Clear (0)

sCellEventTrap-09-
d1(13602513)

13602513

This event occurs when an HSV300
controller needs attention.

Critical(5)

sCellEventTrap-09-
d2(13602514)

13602514

This event occurs when an HSV300
controller blower 1 is removed.

Critical(5)

sCellEventTrap-09-
d3(13602515)

13602515

This event occurs when at least one
Virtual Disk associated with a Data

Replication Group transitions to the
INOPERATIVE state. The remaining

Virtual Disks associated with this Data
Replication Group are forced to the
INOPERATIVE state.

Critical(5)

sCellEventTrap-09-
d4(13602516)

13602516

This event occurs when all the Virtual
Disks associated with a Data Replication

Group transition to the OPERATIVE state.

Clear (0)

sCellEventTrap-09-

d5(13602517)

13602517

This event occurs when the state of a

physical disk drive transitions to the
Single Port on Fibre state.

Clear (0)

sCellEventTrap-09-
d6(13602518)

13602518

This event occurs when an HSV300
controller powers off because the

temperature sensors do not agree and the
system temperature cannot be accurately
determined.

Minor(3)

sCellEventTrap-09-
d7(13602519)

13602519

This event occurs when an HSV300
controller powers off because the

temperature sensors cannot be accessed
and the system temperature cannot be
accurately determined.

Minor(3)

sCellEventTrap-09-
d8(13602520)

13602520

This event occurs when a Redundant
Storage Set has two members on the

same Fibre Channel device enclosure
causing a Disk Group to lose its Single
Point of Failure Robust Configuration.

Critical(5)

sCellEventTrap-09-

d9(13602521)

13602521

This event occurs when a Disk Group

attains a Single Point of Failure Robust
Configuration.

Clear (0)

sCellEventTrap-09-

da(13602522)

13602522

This event occurs when an HSV300

controller blower 1 is running at normal
speed.

Clear (0)

sCellEventTrap-09-

13602523

This event occurs when an HSV300

Clear (0)